Pairing R3c with Face ID X

Monday, December 23, 2019 TimeTec 0 Comments



Master-slave is a model communication or process to controls one or more other devices that serve as their communication hub. One device will act as the Master control and other devices will automatically label as the slave terminal(s). In this case, we will be using the new Face ID X pairs with the R3c device as an example.

Requirement
-         Master device ( Face ID X )
-         Slave device ( R3c )
-         12V Power Supply
-         RS485 Power and communication cable

Wiring diagram

Setting up the Master-slave function
Changing the serial port setting:
By the device screen, select MENU > select Comm > select Serial Comm > select Serial Port > select Master Unit.
 Verification Type:
Go to MENU > Access control > Access control options > Verify mode > select Verification type

Anti-Passback Setup (optional)
A security protocol that prevents users from entering an area twice without exiting the premise at all (the card/fingerprint will auto deny access of the same user who tries to enter the door for a second attempt).
MENU > Access control > Access control options > Anti-passback setup > Device status (for Face ID x either IN/OUT) > Anti-passback Direction (Select the preferred setup users wish to apply)
Device Status Setting
Anti-passback Direction Setting

Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at info@timeteccloud.com, we will update it as soon as possible.